Opel Vectra B

since 1995 of release

Repair and car operation



Vektr B. Opel
+ 1.1. Governing bodies and control devices
+ 2. Maintenance
+ 3. Engines
+ 4. Heating, ventilation
+ 5. Fuel system
+ 6. Systems of start, ignition
- 7. Transmission
   + 7.1. Coupling
   + 7.2. Mechanical transmission
   - 7.3. Automatic transmission
      7.3.1. Introduction
      7.3.2. Technical characteristics
      7.3.3. Oil replacement in a transmission
      7.3.4. Adjustment of the lever of the selector
      7.3.5. Selector cable
      7.3.6. Selector lever
      7.3.7. Replacement of a sealing ring of the hydrotransformer
      7.3.8. Electric elements of management of a transmission
      7.3.9. Switch of a manner of movement
      7.3.10. Electronic control device
      7.3.11. Sensors of an entrance and conducted shaft of a transmission
      7.3.12. Sensor of temperature of oil of a transmission
      7.3.13. Removal and transmission installation
      7.3.14. Major maintenance of a transmission
   + 7.4. Power shafts
+ 8. Brake system
+ 9. Running gear
+ 10. Body
+ 11. Electric equipment
+ 12. Main malfunctions


5645d6d1

7.3.4. Adjustment of the lever of the selector

GENERAL INFORMATION

Prevention

If shutdown of the accumulator is made with the selector lever in situation P, the lever will be fixed in this situation.


PERFORMANCE ORDER
1. For release of the lever from fixing remove furnish of the lever of the selector and, using an edge of a thin screw-driver, press the clamp lever on the left forward side of the lever of the selector.
2. Move the selector lever to all provisions and check that the included transfer correctly is displayed on the indicator of position of the lever of the selector.
3. Establish the selector lever in situation P.
4. For access to a cable of a choice of transfers remove the accumulator and an accumulator support.
5. Take a bracket of blocking and release a cover of a cable of a choice of transfers from an arm on the top part of a transmission.
6. Check that the lever of the selector (1) is established in situation P (2), then move the lever to all provisions and establish it in a starting position. Fix a cover of a cable of the selector in pressing of a bracket of blocking before click.
7. Establish the accumulator and check operation of the lever of the selector.